New spectrophotometric methods for the determination of moxifloxacin in pharmaceutical formulations

Abdalla A Elbashir1, Sara A M Ebraheem, Alawia H E Elwagee

  • 1Department of Chemistry, Faculty of Science, University of Khartoum, Khartoum 11115, P.O. Box 321, Sudan.

Related Concept Videos

Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Measurement of Bioavailability: Pharmacodynamic Methods01:20

Measurement of Bioavailability: Pharmacodynamic Methods

Pharmacodynamic methods provide insights into a drug's effects on physiological processes over time and play a crucial role in understanding bioavailability and therapeutic efficacy. These methods can be broadly classified into acute pharmacological and therapeutic response approaches, each with distinct mechanisms and applications.The acute pharmacological response method directly correlates a drug's physiological effects, such as ECG or pupil diameter changes, to its time course in the body.
Measurement of Bioavailability: Pharmacokinetic Methods01:30

Measurement of Bioavailability: Pharmacokinetic Methods

Pharmacokinetics is a vital branch of pharmacology that examines how drugs are absorbed, distributed, metabolized, and excreted by the body. Two key methodologies in pharmacokinetics are plasma drug concentration studies and urinary drug excretion analyses, both of which provide critical insights into a drug's therapeutic efficacy and bioavailability.Plasma Drug Concentration-Time StudiesPlasma drug concentration-time studies involve analyzing blood samples at specific intervals to quantify...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Protein-Drug Binding: Determination Methods01:22

Protein-Drug Binding: Determination Methods

Determining protein-drug binding can be achieved through indirect and direct methods, each providing valuable insights into the interaction between proteins and drugs.
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...