Reliability analysis and comparison of demodulation methods for dual-beam wavelength-modulation spectroscopy water
Cunguang Zhu1, Jun Chang, Pengpeng Wang
1School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan, China.
Abstract:
Subtraction, division, and balanced ratiometric detection (BRD) are three extensively used demodulation methods for dual-beam wavelength-modulation trace gas detection. However, reliability comparisons among these methods under changing environmental conditions were rarely researched. In this paper, the influences of ambient temperature and bend loss of fibers are analyzed in detail, and the reliabilities of the subtraction, division, and BRD methods are quantitatively compared for the first time to our knowledge. When the ambient temperature is increased by 1°C, the deviation of the division method is only 0.29%, which obviously outperforms the subtraction method (2.90%) and the BRD method (0.55%). Furthermore, a concept, "power fluctuation rejection ratio," is introduced to compare the suppression effects of the subtraction, division, and BRD methods on the laser light source power fluctuation. The study results demonstrate that the division method provides better reliability when the ambient temperature or bending loss is varied. The validity and reliability are fully verified by the fact that the experimental results give good agreement with the theoretical simulation.
More Related Videos
Related Concept Videos
UV–Vis Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...