Spatial-spectral coupling in coherent anti-Stokes Raman scattering microscopy
Related Experiment Video
Updated: May 9, 2026

Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
Published on: July 25, 2022
Aaron M Barlow1, Konstantin Popov, Marco Andreana
1Department of Physics, University of Ottawa, Ottawa ON, Canada. abarlow@uottawa.ca
Abstract:
Coherent anti-Stokes Raman scattering (CARS) microscopy is a third-order nonlinear optical technique which permits label-free, molecule-specific hyperspectral imaging. The interference between coherent resonant and non-resonant terms leads to well known distortions in the vibrational spectrum, requiring the use of retrieval algorithms. It also leads to spatial imaging distortions, largely due to the Gouy phase, when objects are smaller than the Rayleigh range. Here we consider that the focal position and spectral contributions to the nonlinear image formation are intrinsically coupled and cannot be corrected by conventional retrieval methods.
More Related Videos
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
12:54Implementation of a Coherent Anti-Stokes Raman Scattering (CARS) System on a Ti:Sapphire and OPO Laser Based Standard Laser Scanning Microscope
Published on: July 17, 2016
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectroscopy: Spin–Spin Coupling
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...