Related Experiment Video
Updated: May 9, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light
Sabbir Liakat1, Kevin A Bors, Tzu-Yung Huang
1Department of Electrical Engineering, Princeton University, Princeton, NJ 08540, USA.
Abstract:
Mid-infrared transmission spectroscopy using broadband mid-infrared or Quantum Cascade laser sources is used to predict glucose concentrations of aqueous and serum solutions containing physiologically relevant amounts of glucose (50-400 mg/dL). We employ partial least squares regression to generate a calibration model using a subset of the spectra taken and to predict concentrations from new spectra. Clinically accurate measurements with respect to a Clarke error grid were made for concentrations as low as 30 mg/dL, regardless of background solvent. These results are an important and encouraging step in the work towards developing a noninvasive in vivo glucose sensor in the mid-infrared.