Related Experiment Video
Updated: May 9, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Reliability of different body temperature measurement sites during aortic surgery
L Göbölös1, A Philipp, P Ugocsai
11Department of Cardiothoracic Surgery, University Hospital Regensburg, Germany.
Objective:
We retrospectively performed a comparative analysis of temperature measurement sites during surgical repair of the thoracic aorta.
Methods:
Between January 2004 and May 2006, 22 patients (mean age: 63 ± 12 years) underwent operations on the thoracic aorta with arterial cannulation of the aortic arch concavity and selective antegrade cerebral perfusion (ACP) during deep hypothermic circulatory arrest (HCA). Indications for surgical intervention were acute type A dissection in 14 (64%) patients, degenerative aneurysm in 6 (27%), aortic infiltration of thymic carcinoma in 1 (4.5%) and intra-aortic stent refixation in 1 (4.5%). Rectal, tympanic and bladder temperatures were evaluated to identify the best reference to arterial blood temperature during HCA and ACP.
Results:
There were no operative deaths and the 30-day mortality rate was 13% (three patients). Permanent neurological deficits were not observed and transient changes occurred in two patients (9%). During re-warming, there was strong correlation between tympanic and arterial blood temperatures (r = 0.9541, p<0.001), in contrast to the rectal and bladder temperature (r = 0.7654, p = n.s; r = 0.7939, p = n.s., respectively).
Conclusion:
We conclude that tympanic temperature measurements correlate with arterial blood temperature monitoring during aortic surgery with HCA and ACP and, therefore, should replace bladder and rectal measurements.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...