Related Experiment Video
Updated: May 9, 2026

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume
Kun Qian1, Takehiro Ando, Kensuke Nakamura
1Graduate School of Engineering, University of Tokyo, Engineering Building No. 14, Room 722, Hongo 7-3-1, Bunkyo, Tokyo, Japan, sen@bmpe.t.u-tokyo.ac.jp.
Purpose:
Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, this study was designed to develop a new algorithm for dynamic segmentation of IJV and determine appropriate indicators to evaluate the circulating blood volume.
Methods:
Our algorithm is based on snake and speckle tracking models. As the region of interest (ROI) of the control points of the snake tracking algorithm was dynamically moved using speckle tracking, ROI size can be decreased leading to a reduction in the tracking error. Some experiments were performed to validate our algorithm. Subsequently, the algorithm was used for the experiment simulating dehydration state among 11 subjects.
Results:
Results of the validation experiment suggest that our algorithm showed higher performance for IJV extraction compared with standard methods. Furthermore, it was revealed that some indices such as the average area of IJV were related to the dehydration state of subjects.
Conclusion:
This study proposed a new algorithm, which was based on snake and speckle tracking models, for dynamic extraction of IJV in ultrasound images. In addition to algorithm validation, it was suggested that some indices the ultrasound image of IJV could be used for the evaluation of the circulating blood volume.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)