Unexpectedly elevated cardiac troponin I level in the patient without acute coronary syndrome
Snjezana Hrabric Vlah1, Jadranko Sokolic, Igor Medved
1Clinical Department of Laboratory Diagnostics, Clinical Hospital Center Rijeka, Rijeka, Croatia. snjezana.hrabric.vlah@gmail.com
Background:
Since cTnI assay is leading test in diagnostic of myocardial infarctions, and it is used for risk assessment in patients with ACS as well as unstable angina pectoris, it is very important to measure its concentration accurately and precisely.
Methods:
Here we report a case in which there was a significant difference in the cTnI concentrations measured by three different methods, which was detected in one patient's sera during preoperative evaluation for cardiac surgery.
Results:
Due to variations in the results for the cTnI concentrations (0.62; 0.13; 0.89 microg/L), the question was raised about the possibility of an interference known to occur in especially rare situations. A 76-year-old male was operated, temporal elevation and subsequent decrease in the concentrations of cTnI were monitored.
Conclusions:
It was observed that results obtain with different assays are not comparable.
Related Concept Videos
Acute Coronary Syndrome I: Introduction
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Myocarditis II: Clinical Features and Diagnostic Tests
Pericarditis II: Clinical Features and Diagnostic Tests