Related Experiment Video
Updated: May 9, 2026

A Screenable In Vivo Assay for Mitochondrial Modulators Using Transgenic Bioluminescent Caenorhabditis elegans
Published on: October 16, 2015
Bioluminescence enhancement through an added washing protocol enabling a greater sensitivity to carbofuran toxicity
Kun Jia1, Evgeni Eltzov, Robert S Marks
1Laboratoire de Nanotechnologie et d'Instrumentation Optique, Institute Charles Delaunay, Université de technologie de Troyes, UMR-STMR CNRS 6279, 12 rue Marie-Curie CS 42060, 10004 Troyes Cedex, France.
Abstract:
The effects of carbofuran toxicity on a genetically modified bacterial strain E. coli DPD2794 were enhanced using a new bioluminescent protocol which consisted of three consecutive steps: incubation, washing and luminescence reading. Specifically, in the first step, several concentrations of carbofuran aqueous solutions were incubated with different bacterial suspensions at recorded optical densities for different lengths of time. Thereafter, the resulting bacterial/toxicant mixtures were centrifuged and the aged cellular supernatant replaced with fresh medium. In the final step, the carbofuran- induced bioluminescence to the exposed E. coli DPD2794 bacteria was shown to provide a faster and higher intensity when recorded at a higher temperature at30°C which is not usually used in the literature. It was found that the incubation time and the replacement of aged cellular medium were essential factors to distinguish different concentrations of carbofuran in the bioluminescent assays. From our results, the optimum incubation time for a "light ON" bioluminescence detection of the effect of carbofuran was 6h. Thanks to the replacement of the aged cellular medium, a group of additional peaks starting around 30min were observed and we used the corresponding areas under the curve (AUC) at different contents of carbofuran to produce the calibration curve. Based on the new protocol, a carbofuran concentration of 0.5pg/mL can be easily determined in a microtiter plate bioluminescent assay, while a non-wash protocol provides an unexplainable order of curve evolutionswhich does not allow the user to determine the concentration.
More Related Videos
04:47Autonomously Bioluminescent Mammalian Cells for Continuous and Real-time Monitoring of Cytotoxicity
Published on: October 28, 2013
09:29In Vivo Investigation of Antimicrobial Blue Light Therapy for Multidrug-resistant Acinetobacter baumannii Burn Infections Using Bioluminescence Imaging
Published on: April 28, 2017