Exaggerated response of systolic blood pressure to cycle ergometer
Young Joo Kim1, Heaja Chun, Chul-Hyun Kim
1Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Seoul, Korea.
Objective:
The aim of this study is to exam the effects of exercise modes on the systolic blood pressure and rate-pressure product during a gradually increasing exercise load from low to high intensity.
Methods:
Fifteen apparently healthy men aged 19 to 23 performed the graded exercise tests on cycle ergometer (CE) and treadmill (TM). During the low-to-maximal exercises, oxygen uptake (VO2), heart rate (HR), systolic blood pressure (SBP) and rate-pressure product were measured.
Results:
CE had a significantly lower maximum VO2 than TM (CE vs. TM: 48.51±1.30 vs. 55.4±1.19 mL/kg/min; p<0.001). However, CE showed a higher maximum SBP (SBPmax) at the all-out exercise load than TM (CE vs. TM: 170±2.4 vs. 154±1.7 mmHg; p<0.001). During the low-to-maximal intensity increment, the slope of the HR with VO2 was the same as VO2 increased in times of the graded exercise test of CE and TM (CE vs. TM: 2.542±0.100 vs. 2.506±0.087; p=0.26). The slope of increase on SBP accompanied by VO2 increase was significantly higher in CE than in TM (CE vs. TM: 1.669±0.117 vs. 1.179±0.063; p<0.001).
Conclusion:
The SBP response is stronger in CE than in TM during the graded exercise test. Therefore, there is a possibility that CE could induce a greater burden on workloads to cardiovascular system in humans than TM.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Blood Pressure