Zeolite imidazolate framework-8 as sorbent for on-line solid-phase extraction coupled with high-performance liquid
Xue-Qing Yang1, Cheng-Xiong Yang, Xiu-Ping Yan
1State Key Laboratory of Medicinal Chemical Biology, Synergetic Innovation Center of Chemical Science and Engineering (Tianjin), and Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China.
Abstract:
Zeolite imidazolate framework-8 (ZIF-8) was used as the novel sorbent for on-line solid-phase extraction coupled with high-performance liquid chromatography (HPLC) for the determination of oxytetracycline (OTC), tetracycline (TC) and chlorotetracycline (CTC) in water and milk samples. 390mg of ZIF-8 was packed into a stainless steel column (3cm long×4.6mm i.d.) which was mounted on the HPLC injector valve to replace the sample loop. On-line solid-phase extraction of OTC, TC and CTC was achieved by loading sample solution at a flow rate of 3.0mLmin(-1) for 10min with the aid of a flow-injection system. The extracted analytes were subsequently eluted into a C18 analytical column (25cm long×4.6mm i.d.) for HPLC separation under isocratic condition with a mobile phase (10% MeOH-20% ACN-70% 0.02molL(-1) oxalic acid solution) at a flow rate of 1.0mLmin(-1). Under optimized conditions, the developed method gave the enhancement factors of 35-61, the linearity range of 5-1000μgL(-1), the detection limits of 1.5-8.0μgL(-1), quantification limits of 5.0-26.7μgL(-1), uncertainties of 0.9-1.1μgL(-1), and the sample throughput of 4 samples h(-1). The recoveries of OTC, TC and CTC at 50μgL(-1) in water and milk samples ranged from 70.3% to 107.4%.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Analyte Adsorption and Distribution
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Extraction: Advanced Methods
