Related Experiment Video
Updated: May 9, 2026

Digital Microfluidics for Automated Proteomic Processing
Published on: November 6, 2009
Multi-dimension microchip-capillary electrophoresis device for determination of functional proteins in infant milk
Ruige Wu1, Zhiping Wang, Wenfeng Zhao
1Singapore Institute of Manufacturing Technology, 71 Nanyang Drive, Singapore 638075, Singapore. rgwu@SIMTech.a-star.edu.sg
Abstract:
To improve resolution of important minor proteins and eliminate time-consuming precipitation of major protein with associated analyte co-precipitation risk, a multi-dimension strategy is adopted in the 2D microchip-CE device to isolate major proteins on-chip, enrich minor proteins in capillary before their separation in CE for UV quantitation. A standard fluorescent protein mixture containing FITC-BSA, myoglobin and cytochrome as specific pI markers has prepared to demonstrate capability of the device to fractionate minor proteins by IEF. The results using a standard protein mixture with profile resembling infant milk formula show a complete isolation of high abundance proteins by a 2-min 1D IEF run. The subsequent t-ITP/CZE run by on-chip high voltage switching delivers a high stacking ratio, realizing 60 folds enrichment of isolated protein fractions. All five important functional proteins (LF, IgG, α-LA, β-LgA and β-LgB) known to fortify infant milk formula are isolated and determined using two consecutive t-ITP-CZE runs within a 18-min total assay time, a significant saving compared to several hours conventional pretreatment. For a 100g infant milk formula sample, working ranges of 20-8000mg, repeatability 3.8-5.3% and detection limits 2.3-10mg have been achieved to meet government regulations. Method reliability is established by 100% recoveries and agreeable results within expected ranges and labeled values. The capability of the device for field operation, rapid assay with quick results, label-free universal detection, simple operation by aqueous dissolution before injection, and the demanding matching in 2D separation based on isolated fractions at specified pI ranges, closely matched migration time and baseline-resolved peak shape makes the device a general tool to detect unknown proteins and determine known minor proteins in protein-rich samples with interfering constituents.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation