Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Detection of extraction artifacts in the analysis of honey volatiles using comprehensive two-dimensional gas
Sandra Regina Rivellino1, Leandro Wang Hantao, Sanja Risticevic
1Institute of Chemistry, University of Campinas - UNICAMP, Campinas, SP, Brazil.
Abstract:
Extraction using headspace solid phase microextraction (HS-SPME) coupled to comprehensive two-dimensional gas chromatography with flame ionisation detection (GC×GC-FID) was employed to evaluate the effect of SPME fractionation conditions (heating time and temperature) on the generation of artifacts. The occurrence of artifacts was more pronounced at higher fractionation temperatures and times which caused significant changes in the chromatographic profiles. The identification of the volatile fraction of the honey blend was performed through a two-dimensional gas chromatograph coupled to a mass spectrometer with time of flight analyser (GC×GC-ToFMS) by comparing the first dimension linear temperature programmed retention index ((1)D-LTPRI) with the peak's identities provided by the mass spectral similarity search. Several artifacts were found and identified - such as hydroxymethylfurfural, methyl-furone and furfural - and some of them were not previously detected as such in honey samples. These compounds were either the result of hydrolysis or thermal decomposition of components already present in the honey samples. This occurrence was attributed to the increased detectability provided by GC×GC compared to conventional GC. The possible emergence of previously unknown extraction artifacts as a general tendency related use of GC×GC instead of conventional GC is discussed as a result of these observations.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Volatilization