Related Experiment Video
Updated: May 9, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
High discordance rates between sub-areolar and peri-tumoural breast lymphoscintigraphy
F Noushi1, A J Spillane, R F Uren
1Discipline of Surgery, Sydney Medical School, University of Sydney, Sydney, Australia; The Mater Hospital, North Sydney, Australia; Royal North Shore Hospital, St Leonards, Australia; Sydney Adventist Hospital, Wahroonga, Australia.
Objective:
To test the hypothesis that sub-areolar (SA) lymphoscintigraphy (LSG) identifies the same sentinel node as peri-tumoural (PT) injections.
Background:
It is commonly believed that all LSG techniques will identify the same sentinel lymph nodes (SLN) draining the breast. Hybrid imaging technology (SPECT/CT) allows accurate identification of the exact location of SLNs. Using SPECT/CT SA and PT LSG techniques were compared.
Method:
In a multi-centre trial 39 patients sequentially underwent LSG (SA followed by PT) separated by 2-7 days. Patients were referred by 4 surgeons to 3 LSG centres, with standardization of isotope (99mTc-antimony sulfide colloid), LSG and SPECT/CT evaluation techniques. LSG were evaluated for SLN concordance and degree of discordance in the axilla and internal mammary nodes (IMN).
Results:
39 eligible patients, median age 62 years, were recruited. Successful axillary SLN mapping for SA and PT injection techniques was 87% and 95% respectively. Successful internal mammary SLN mapping occurred with SA and PT LSG in 5% and 36% respectively. Discordance was identified in the IMN (39%) and axilla (21%), with an overall rate of discordance between SA and PT LSG of 56%.
Conclusions:
There is a high level of discordance in the localization of SLN by these commonly used LSG injection techniques. This discordance has implications for accuracy of axillary and extra-axillary staging and could impact on patient outcome.