Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM
Robert M Glaeser1, Simone Sassolini, Rossana Cambie
1Life Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720, USA.
Abstract:
Microfabricated devices designed to provide phase contrast in the transmission electron microscope must be free of phase distortions caused by unexpected electrostatic effects. We find that such phase distortions occur even when a device is heated to 300 °C during use in order to avoid the formation of polymerized, carbonaceous contamination. Remaining factors that could cause unwanted phase distortions include patchy variations in the work function of a clean metal surface, radiation-induced formation of a localized oxide layer, and creation of a contact potential between an irradiated area and the surround due to radiation-induced structural changes. We show that coating a microfabricated device with evaporated carbon apparently eliminates the problem of patchy variation in the work function. Furthermore, we show that a carbon-coated titanium device is superior to a carbon-coated gold device, with respect to radiation-induced electrostatic effects. A carbon-coated, hybrid double-sideband/single-sideband aperture is used to record in-focus, cryo-EM images of monolayer crystals of streptavidin. Images showing no systematic phase error due to charging are achievable under conditions of low-dose data collection. The contrast in such in-focus images is sufficient that one can readily see individual streptavidin tetramer molecules. Nevertheless, these carbon-coated devices perform well for only a limited length of time, and the cause of failure is not yet understood.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Transmission Electron Microscopy