Absolute spectral responsivity measurements of solar cells by a hybrid optical technique
Behrang H Hamadani1, John Roller, Brian Dougherty
1Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA. behrang.hamadani@nist.gov
Abstract:
An irradiance mode, absolute differential spectral response measurement system for solar cells is presented. The system is based on combining the monochromator-based approach of determining the power mode spectral responsivity of cells with an LED-based measurement to construct a curve representing the light-overfilled absolute spectral response of the entire cell. This curve can be used to predict the short-circuit current (I(sc)) of the cell under the AM 1.5 standard reference spectrum. The measurement system is SI-traceable via detectors with primary calibrations linked to the NIST absolute cryogenic radiometer. An uncertainty analysis of the methodology places the relative uncertainty of the calculated I(sc) at better than ±0.8%.
Related Concept Videos
UV–Vis Spectrometers
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Measuring Reaction Rates