Over 600 operating room fires occur annually although many cases go unreported. Over 81% of operating room fires involve surgical drapes, yet limited data exist on the differing degrees of flammability of drapes and other surgical fuel sources in varying oxygen concentrations. The purpose of this study is to assess the flammability characteristics of fuels in the operating room under varying oxygen concentrations.
Methods:
Five fuel sources were analyzed in three levels of oxygen: 21%, 50%, and 100%. Three test samples of each material were burned in a manner similar to that established by the Consumer Product Safety Commission. Time to sample ignition and time to complete burn were measured with video analysis.
Results:
The median [minimum, maximum] ignition time in 21% oxygen was 0.9 s [0.3, 1.9], in 50% oxygen 0.4 s [0.1, 1.2], and in 100% oxygen 0.2 s [0.0, 0.4]. The median burn time in 21% oxygen was 20.4 s [7.8, 33.5], in 50% oxygen 3.1 s [1.4, 8.1], and in 100% oxygen 1.7 s [0.6, 2.7]. Time to ignite and total burn times decreased as oxygen concentration increased (P < 0.001). Flammability characteristics differed by material and oxygen concentration. Utility drapes and surgical gowns did not support combustion in room air, whereas other materials quickly ignited. Flash fires were detected on woven cotton materials in oxygen-enriched environments.
Conclusions:
Operating room personnel should be aware that common materials in the operating room support rapid combustion in oxygen-enriched environments. The risk of ignition and speed of fire propagation increase as oxygen exposure increases. Advances in material science may reduce perioperative fire risk.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Requirements and Growth Patterns
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.