Related Experiment Video
Updated: May 9, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of post diameter and cement thickness on bond strength of fiber posts
Objective:
This study evaluated the effects of different post diameter and oversized post spaces on the push-out bond strength of a fiber post to dentin.
Method And Materials:
Fifty extracted human maxillary central incisors and canines were divided into five groups and submitted to the push-out test (0.5 mm min-1). Groups 1, 2, and 3 were restored using a fiber post size that was identical to the drill size (sizes 1, 2, and 3, respectively), and groups 4 and 5 were both prepared with drill size 3, and restored using the size 2 and 1 fiber post, respectively. The fiber posts were cemented using self-adhesive dual-polymerized resin cement (RelyX Unicem). The data were analyzed using a one-way analysis of variance (ANOVA) and the Tukey test.
Results:
There were no significant differences in the mean values for push-out bond strength between groups with different post diameters (P > .05). However, the push-out bond strengths were significantly different between groups with different cement thicknesses, and group 4 yielded the highest bond strength (11.7 ± 0.4 MPa). For all groups, the apical third had the lowest bond strength value (P < .05).
Conclusion:
The highest push-out bond strength values were obtained when one incremental oversized post space was used. Clinically, fiber post space has to provide an optimum cement thickness (around 120 µm) for adequate cementation.
Related Concept Videos
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Fiber Reinforced Concrete
Pore Size Distribution
Adequate...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...