Related Experiment Video
Updated: May 9, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
JOURNAL CLUB: CT dose optimization for whole-body PET/CT examinations
Elena Tonkopi1, Andrew A Ross, Anita MacDonald
1Department of Diagnostic Radiology, Dalhousie University, 1276 South Park St, Halifax, NS, B3H 2Y9, Canada. elena.tonkopi@cdha.nshealth.ca
Abstract:
OBJECTIVE. The objective of this study was to optimize CT protocols for whole-body PET/CT by reducing radiation dose while minimizing effects on image quality. MATERIALS AND METHODS. Before protocol optimization, a survey of 140 consecutive patients was conducted to establish the baseline dose from a whole-body PET/CT examination. Another sample of 100 patients was surveyed to evaluate the reduction of radiation dose after implementation of the new protocol. Effective dose from the CT component of the examination was estimated using dose-length product (DLP) values from reports generated by the scanner and anatomy-specific conversion factors. Twenty-six patients who underwent studies before and after the optimization were included in an analysis of image quality. All 26 patients had maintained the same weight between the examinations and were scanned in the same position using a similar technique except for the changes made for CT dose optimization. The studies were randomized and blinded for an experienced PET and CT reader who graded the imaging quality of anatomic structures. RESULTS. CT protocol optimization resulted in a 32% reduction of the mean CT radiation dose: The mean effective dose was reduced from 8.1 to 5.5 mSv. The blinded analysis of image quality showed no clinically significant degradation of the lower-dose studies. The only structures visualized statistically better on the higher-dose CT scans were the carotid arteries and the region of the posterior triangle. CONCLUSION. The results of this study showed that optimization of CT acquisition can effectively reduce radiation dose in a whole-body PET/CT examination without significantly sacrificing image quality.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...