Related Experiment Video
Updated: May 9, 2026

Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
Retention prediction and separation optimization of ionizable analytes in reversed-phase liquid chromatography by
S Fasoula1, Ch Zisi, P Nikitas
1Laboratory of Physical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Abstract:
The influence of eluent pH on retention of ionizable analytes during organic modifier gradients in reversed-phase high performance liquid chromatography is studied. Two approaches are examined for the retention prediction of solutes under organic modifier gradient conditions at any constant mobile phase pH: In the first approach an analytical solution of the fundamental equation of gradient elution in linear organic modifier gradients for monoprotic acids/bases under certain assumptions is proposed. The second approach is based on an empirical model arising from the evaluation of the gradient retention data. Both approaches were successfully applied to describe the retention behavior of 16 OPA derivatives of amino acids obtained in 19 simple mono-linear organic modifier gradient runs performed between two given acetonitrile contents with different gradient duration and at different eluent pHs, in a particular pH range where amino acids behave as weak monoprotic acids. Further, this study provides a reliable way for optimizing gradient separations of ionogenic compounds with respect to mobile phase pH.
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
