Introduction:
This study aims to quantify the radiobiology of the MammoSite applicator and examine whether there is a relationship between equivalent uniform dose (EUD) and radiotherapy-associated toxicity.
Methods And Materials:
A previously-published version of the linear quadratic (LQ) model, designed to address the impact of dose-gradients in brachytherapy applications, was used to determine the biological effective dose (BED), equivalent dose in 2 Gray per fraction (EQD2) and EUD for the most common fractionation scheme for the MammoSite catheter (34 Gy in 10 fractions prescribed to 1cm from the balloon surface), using a range of balloon sizes in a series of patients treated with single or multiple dwell positions. Toxicity from the MammoSite catheter was assessed and statistical associations with the calculated EUDs were investigated.
Results:
The acute- and late-toxicity EUDs respectively range from 34.8-39.4 Gy and 33.4-37.6 Gy, with EUD decreasing as balloon diameter increases and/or the number of dwell positions increases. There was a positive association between EUD and hyperpigmentation and telangiectasia.
Conclusions:
For APBI using the Mammosite applicator, EUD is higher than the marginal prescription dose and, for the dose-fractionation patterns considered here, was associated with acute and late skin toxicity. EUD is a potentially useful parameter to characterize non-uniform dose distributions related to brachytherapy treatments. Further evaluation in future studies is warranted.