Collaborative study of an on-column periodate reaction method for the determination of ephedrine sulfate in sirups

Journal - Association of Official Analytical Chemists
|July 1, 1975
PubMed

Related Concept Videos

Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Adrenergic Agonists: Mixed-Action Agents01:28

Adrenergic Agonists: Mixed-Action Agents

Mixed-action adrenergic agonists, like ephedrine and pseudoephedrine, directly and indirectly affect adrenergic receptors. These agents stimulate adrenoceptors and indirectly release stored neurotransmitters, amplifying the adrenergic response.
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...