Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Dynamic sonographic measurements at the carpal tunnel inlet: reliability and reference values in healthy wrists
Anika Filius1, Jan-Wiebe H Korstanje, Ruud W Selles
1Department of Plastic and Reconstructive Surgery and Hand Surgery, Erasmus MC, University Medical Centre Rotterdam, P.O. Box 2040, 3000CA, Rotterdam, The Netherlands.
Introduction:
Reliability and reference values are not well-established for most dynamic sonographic measurements of the median nerve (MN) and flexor tendons that may be used for diagnosing carpal tunnel syndrome (CTS).
Methods:
Wrists of 20 healthy participants were imaged using ultrasound. Cines of the carpal tunnel inlet were acquired during hand motion. Based on shape and displacement measurements, intra- and interrater reliability and reference values were calculated.
Results:
Intraclass correlation coefficients (ICCs) for measurements of the MN and most flexor tendons were ≥0.51 for shape parameters and ≥0.71 for displacement parameters. During motion, the MN flattened with ulnar movement, tendons became more circular, and flexor tendons of corresponding fingers moved toward each other.
Conclusion:
Shape and displacement measurements of the MN and most flexor tendons had reliability results ranging from moderate to excellent. The reference values may be useful for the diagnosis of CTS.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement