Alternative ear-canal measures related to absorbance
Stephen T Neely1, Stefan Stenfelt, Kim S Schairer
1Department of Hearing Research, Boys Town National Research Hospital, Omaha, Nebraska 68131, USA.
Ear and Hearing
|August 1, 2013
Summary
Several alternative ear-canal measures, including sound intensity and reflectance, offer advanced insights beyond traditional absorbance. These methods improve accuracy in auditory research and diagnostics.
Area of Science:
- Audiology
- Acoustics
- Bioacoustics
Background:
- Traditional ear-canal absorbance measurements require a Thévenin-equivalent sound source.
- Alternative measures like sound intensity level and reflectance are being explored.
Purpose of the Study:
- To introduce and compare alternative ear-canal measures to absorbance.
- To highlight the potential benefits of these novel measures for auditory research and diagnostics.
Main Methods:
- Comparison of sound intensity level, forward pressure level, time-domain ear-canal reflectance, and cochlear reflectance with absorbance.
- Analysis of wideband stimuli and ear-canal sound pressure recordings.
Main Results:
- Sound intensity and forward pressure levels reduce calibration errors from standing waves compared to sound pressure level.
- Time-domain ear-canal reflectance shows potential for estimating ear-canal geometry and assessing middle ear pathology.
- Cochlear reflectance provides inner ear information akin to otoacoustic emissions with potential interpretive advantages.
Conclusions:
- Alternative ear-canal measures offer distinct advantages over traditional absorbance.
- These measures enhance the accuracy and scope of auditory assessments, from behavioral thresholds to inner ear diagnostics.
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
In vitro experiments are crucial for understanding the transport and absorption of drugs through biological materials. These studies employ varied methods such as the diffusion cell method, the everted sac technique, and the everted ring technique.
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...