Adverse events and technical complaints related to central venous catheters marketed in Brazil
Luciene de Oliveira Morais1, Karen Friedrich, Stela Candioto Melchior
1Fundação Oswaldo Cruz, FIOCRUZ, Rio de Janeiro, RJ, Brazil.
Aim:
The objective of this study was to critically analyze data of the National Notification System for Adverse Events and Technical Complaints (Notivisa) related to central venous catheters, through an evaluation of the description of notifications recorded between 2006 and 2009.
Methods:
NOTIFICATIONS WERE CATEGORIZED AND EVALUATED TO: (i) determine the number of adverse events and technical complaints, (ii) verify compliance with the classification criteria defined by the legislation, (iii) reclassify notifications, when necessary, in order for them to fit in with the legal definitions, (iv) verify registered companies in Brazil, (v) quantify the notifications according to the registered company and product lot, and (vi) identify the country of original of the notified product. Microsoft Excel((r)) 2010 was used to categorize and systematize the data.
Results:
Some conceptual errors and incomplete records were found. Altogether, 228 notifications of technical complaints and 119 of adverse events were identified. Some notifications on guidewires and broken catheters were reported which led to the necessity of duplicating some medical procedures and to the occurrence of lesions/lacerations of vessels and tissue injury. Forty-seven percent of companies presented at least one notification in Notivisa and in all, 38 product lots had more than one notification.
Conclusion:
These data support a necessity for cooperation between all entities of the National Health Surveillance System to check compliance of this type of product and to properly report adverse events and technical complaints. It is also important to incorporate minimum standards for the management of technologies in health services, including in the acquisition of products and training of staff.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
05:51Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Endocarditis IV: Nursing Management
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization IV: Nursing Management
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Venous Thrombosis IV: Nursing Management