Related Experiment Video
Updated: May 9, 2026

Unraveling Entropic Rate Acceleration Induced by Solvent Dynamics in Membrane Enzymes
Published on: January 16, 2016
Determination of the kinetic rate constant of cyclodextrin supramolecular systems by high performance affinity
Haiyan Li1, Jingwen Ge, Tao Guo
1Center for Drug Delivery System, Shanghai Institute of Materia Medica, State Key Laboratory of Drug Research, Chinese Academy of Sciences, Shanghai 201203, China.
Abstract:
It is challenging and extremely difficult to measure the kinetics of supramolecular systems with extensive, weak binding (Ka<10(5)M(-1)), and fast dissociation, such as those composed of cyclodextrins and drugs. In this study, a modified peak profiling method based on high performance affinity chromatography (HPAC) was established to determine the dissociation rate constant of cyclodextrin supramolecular systems. The interactions of β-cyclodextrin with acetaminophen and sertraline were used to exemplify the method. The retention times, variances and the plate heights of the peaks for acetaminophen or sertraline, conventional non-retained substance (H2O) on the β-cyclodextrin bonded column and a control column were determined at four flow rates under linear elution conditions. Then, plate heights for the theoretical non-retained substance were estimated by the modified HPAC method, in consideration of the diffusion and stagnant mobile phase mass transfer. As a result, apparent dissociation rate constants of 1.82 (±0.01)s(-1) and 3.55 (±0.37)s(-1) were estimated for acetaminophen and sertraline respectively at pH 6.8 and 25°C with multiple flow rates. Following subtraction of the non-specific binding with the support, dissociation rate constants were estimated as 1.78 (±0.00) and 1.91 (±0.02)s(-1) for acetaminophen and sertraline, respectively. These results for acetaminophen and sertraline were in good agreement with the magnitude of the rate constants for other drugs determined by capillary electrophoresis reported in the literature and the peak fitting method we performed. The method described in this work is thought to be suitable for other supramolecules, with relatively weak, fast and extensive interactions.
More Related Videos
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
14:27Steady-state, Pre-steady-state, and Single-turnover Kinetic Measurement for DNA Glycosylase Activity
Published on: August 19, 2013
Related Concept Videos
Ion-Exchange Chromatography
Affinity Chromatography
Analyte Adsorption and Distribution
Determining Order of Reaction
Determination of Molar Masses of Polymers II
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...