Related Experiment Video
Updated: May 9, 2026

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Anodic stripping voltammetric determination of cadmium using a "mercury free" indium film electrode
Sukeri Anandhakumar1, Jayaraman Mathiyarasu, Kanala Lakshimi Narasimha Phani
1Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute, Karaikudi, 630006, Tamil Nadu, India. almathi@cecri.res.in.
Abstract:
In this work, the determination of cadmium has been attempted using an indium film electrode in the presence of bromide ions as an additive, for the first time. The electrode was prepared in situ on a glassy carbon substrate and employed in combination with square wave anodic stripping voltammetry. The purpose of having bromide ions is to enhance the analytical value of cadmium detection. In the absence of bromide ions, cadmium stripping peaks coalesce with indium and it is difficult to resolve for analytical purposes. The addition of bromide ions strongly influences the peak separation, thanks to the complex-forming characteristics of cadmium with bromide ions. Several key operational parameters influencing the electroanalytical response of indium modified electrodes were examined and optimized, such as deposition potential, pH, bromide ion and indium concentration. The indium modified electrode exhibited well-defined, separated stripping signals and revealed good linear behavior in the examined concentration range from 1 to 25 ng ml(-1). The present method shows a low detection limit value of 0.36 ng ml(-1). These results suggest that the proposed electrode contributes to the wider applicability of electrochemical stripping techniques in connection with "mercury-free" electrodes.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry
Electrodeposition
Electrodeposition can...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
