Related Experiment Video
Updated: May 9, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Spontaneous urinary voiding of metallic screws in a patient with symphyseal plating for type II pelvic ring
Sanjay Yadav1, Naresh Chander Arora, Manish Prasad
1Department of Orthopaedics, Base Hospital and Army College of Medical Sciences, New Delhi 110010, India.
Abstract:
With rapid advancement in surgical techniques and improvement in implant materials, rate of internal fixation for pubic symphyseal disruption in rotationally and vertically unstable pelvic ring injuries has increased. Among various modes of implant failure, screw/plate breakage and loosening are common complications following unstable fixation. Migration of loose screws into the urinary bladder has been reported as an extremely uncommon complication of pubic symphyseal plating. Here we present a case report of a 52-year-old female who presented with asymptomatic passage of screws in her urine following migration into the bladder, 2 years after symphyseal plating for pubic diastasis in an anteroposterior compression pelvic ring injury.
Related Concept Videos
Urinary Tract Calculi VI: Surgical Management
Urinary Tract Calculi III: Medical Management
Urinary Tract Calculi II: Pathophysiology and Clinical Manifestations
Urinary Tract Calculi V: Nursing Management