[MRI investigations in patients with problems due to metal-on-metal implants]
Abstract:
Until recently, metal-on-metal (MoM) hip implants were commonly used for joint replacement and resurfacings. Their use has rapidly declined following reports of Frühversagen and soft tissue disease caused by the release of metal debris from the prosthesis. Detection of these soft tissue lesions has proven difficult using conventional imaging techniques and blood metal ion tests. Current guidelines recommend the use of imaging modalities including metal artefact reduction sequence (MARS) magnetic resonance imaging (MRI), computed tomography and ultrasound but provide little indication which is best. MARS significantly reduces the susceptibility artefact induced by the presence of metal objects, thereby producing diagnostic quality images that can be shared with other physicians and compared over time. The clinical interpretation of MRI findings of solid pseudotumours and severe muscle atrophy is straightforward: revision is usually recommended. However, the most common MRI findings are of a cystic pseudotumour and minor muscle wasting. In these cases decision-making is difficult and we currently use multi-disciplinary and multi-colleague based meetings to make decisions regarding patient management. This article presents a comparison of imaging modalities and an update on the interpretation of MARS MRI for the investigation of patients with MoM hip implants.The English full-text version of this article is available at Springer Link (under "Supplemental").
Insights
Metal-on-metal hip implants can cause soft tissue issues. Metal artefact reduction sequence (MARS) magnetic resonance imaging (MRI) aids in detecting these problems, improving patient management decisions.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Radiology
Context:
- Metal-on-metal (MoM) hip implants were widely used but are now declining due to adverse tissue reactions from metal debris.
- Detecting these soft tissue complications is challenging with standard imaging and blood tests.
Purpose:
- To compare various imaging modalities for MoM hip implants.
- To provide an updated interpretation of MARS MRI findings for MoM hip implant complications.
Summary:
- MARS MRI significantly reduces metal artifacts, enabling diagnostic quality imaging for MoM hip implant complications.
- While solid pseudotumors and severe muscle atrophy on MARS MRI clearly indicate revision, cystic pseudotumors and minor muscle wasting present diagnostic challenges.
- The article reviews imaging options and MARS MRI interpretation to aid in managing patients with MoM hip implants.
Impact:
- Improved diagnostic accuracy for MoM hip implant complications.
- Facilitates better clinical decision-making in challenging cases, potentially leading to more timely and appropriate interventions.
- Enhances understanding of MARS MRI utility in managing adverse reactions to MoM hip implants.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...