Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
In-line sequential injection-based hollow-fiber sorptive microextraction as a front-end to gas chromatography-mass
Warunya Boonjob1, José Benito Quintana, Rosario Rodil
1FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, 07122, Palma de Mallorca, Illes Balears, Spain.
Abstract:
A novel and affordable analytical setup is herein reported for automatic flow-through sorptive microextraction of organic contaminants, exploiting polydimethylsiloxane (PDMS) as a front-end to gas chromatography-ion trap-tandem mass spectrometry. The analytical procedure involves a short single-strand PDMS hollow fiber integrated in a sequential injection (SI) network for automatic fluidic handling by programmable flow. The target species are in-line extracted from 10 mL of sample containing 20% (v/v) methanol followed by elution with a metered volume of organic solvent, which is whereupon quantitatively transferred into the programmed temperature vaporization (PTV) injector of the GC. Diffusional resistance to mass transfer was overcome by effecting the overall concentration and stripping steps at a single PDMS tubing interface. The proof of concept of the novel hyphenated system was demonstrated for extraction and determination of organochlorine pesticides (OCPs), namely, heptachlor, dieldrin, endrin, endosulfan, p,p'-dichlorodiphenyldichloroethane, p,p'-dichlorodiphenyltrichloroethane, dichlorodiphenyldichloroethylene, and endrin ketone, taken as model analytes, in environmental and industrial waters. Four organic solvents with a broad spectrum of polarity were investigated as eluents in the SI-based assembly, namely, ethyl acetate, methyl tert-butyl ether, hexane, and chloroform. Chloroform was proven the most suitable solvent for expedient elution and fast evaporation in the PTV injector. Under the selected experimental variables, limits of detection (signal-to-noise ratio (S/N) = 3) within the range of 0.3-1.1 ng L(-1), limits of quantification (S/N = 10) of 1.0-3.6 ng L(-1), and method repeatabilities spanning from 1.7 to 4.7% were obtained for the suite of OCPs. The hyphenated flow analyzer was harnessed to the analysis of samples of varying matrix complexity with good relative recoveries (86-112%) in drinking water, surface water, and influent and effluent wastewaters, with quantification limits far below those endorsed by WHO and EU drinking water directives setting maximum allowed concentrations at ≤100 ng L(-1) OCPs.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.