Related Experiment Video
Updated: May 9, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Electronic documentation of central venous catheter-days: validation is essential
Sheri Chernetsky Tejedor1, Gina Garrett, Jesse T Jacob
1Division of Hospital Medicine, Department of Medicine, Emory University School of Medicine, Atlanta, Georgia 30329, USA. scherne@emory.edu
Background:
Measurement of central line-associated bloodstream infection (CLABSI) rates outside of intensive care units is challenged by the difficulty in reliably determining central venous catheter (CVC) use. The National Healthcare Safety Network (NHSN) allows for use of electronic data for determination of CVC-days, but validation of electronic data has not been studied systematically.
Objective:
To design and validate a process to reliably measure CVC-days outside of the intensive care units that leverages electronic documentation.
Methods:
Thirty-four inpatient wards at 2 academic hospitals using a common electronic platform for nursing documentation were studied. Electronic queries were created to capture patient and CVC information, and tools and processes for tracking and reporting errors in documentation were developed. Strategies to validate electronic data included comparisons with manual CVC-day determinations and automated data validation using customized tools. Interventions included redesign of documentation interface, real-time audit with feedback of errors, and education. The primary outcome was patient-level total error rate in electronic CVC-day measurement compared with manually counted CVC-days.
Results:
At baseline, there were a mean (± standard deviation) of [Formula: see text] electronic CVC-day errors (omission and commission errors summed and counted equally) per manually counted CVC-day. After several process improvement cycles over 7 months, the error rate decreased to <0.05 errors per CVC-day and remained at or below this level for 2 years.
Conclusions:
Baseline electronic CVC-day counts had a high error rate. Stepwise interventions reduced errors to consistently low levels. Validation of electronic calculation of CVC-days is essential to ensure accuracy, particularly if these data will be used for interinstitutional comparison.
More Related Videos
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Related Concept Videos
Methods of Documentation V: CBE
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...
Guidelines for Nursing Documentation I
Factual:
The following points emphasize the significance of upholding accurate and unbiased documentation in healthcare.
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Legal Guidelines for Documentation