Comparison of preoperative and postoperative ocular biometry in eyes with phakic intraocular lens implantations
Related Experiment Video
Updated: May 9, 2026

Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
Published on: September 20, 2024
Joo Youn Shin1, Jae Bum Lee, Kyoung Yul Seo
1Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
Purpose:
To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex.
Materials And Methods:
This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation.
Results:
ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL.
Conclusion:
ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.