Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Unilateral corneal ectasia following trigeminal schwannoma resection with chronic neurogenic eye rubbing.

American journal of ophthalmology case reports·2026
Same author

Relationship Between Scheimpflug-Based Ocular Biomechanics and Myopia Progression in Adolescents.

Bioengineering (Basel, Switzerland)·2026
Same author

Relationship Between Scheimpflug-Based Ocular Biomechanics and Myopic Maculopathy.

Bioengineering (Basel, Switzerland)·2026
Same author

Comparison of the Ratio Between Anterior and Posterior Curvature Centered on the Thinnest Point (A/B Ratio) in Normal and Keratoconus Eyes.

Translational vision science & technology·2026
Same author

Hereditary gelsolin amyloidosis in Brazil: case report and brief review of the literature.

Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology·2026
Same author

Heterogeneous Longitudinal Changes in Corneal Epithelial and Stromal Thicknesses in Patients With Very Asymmetric Ectasia: A Case Series.

Eye & contact lens·2026

Related Experiment Video

Updated: Jan 9, 2026

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

2.0K

Scheimpflug imaging for keratoconus and ectatic disease.

Michael W Belin1, Renato Ambrósio

  • 1Southern Arizona VA Healthcare System, University of Arizona, Tucson, Arizona, USA.

Indian Journal of Ophthalmology
|August 9, 2013
PubMed
Summary

Scheimpflug imaging provides superior anterior segment analysis compared to older methods. This advanced technique enables earlier detection of corneal ectasia and peripheral diseases like pellucid marginal degeneration.

More Related Videos

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Published on: July 24, 2020

3.4K
Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
11:29

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies

Published on: January 3, 2011

27.2K

Related Experiment Videos

Last Updated: Jan 9, 2026

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

2.0K
In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Published on: July 24, 2020

3.4K
Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
11:29

Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies

Published on: January 3, 2011

27.2K

Area of Science:

  • Ophthalmology
  • Medical Imaging
  • Corneal Science

Background:

  • Traditional methods like Placido-based topography and ultrasound pachymetry have limitations in corneal imaging.
  • These methods may not detect subtle changes indicative of early corneal ectasia or peripheral diseases.

Purpose of the Study:

  • To highlight the advantages of Scheimpflug cross-sectioning anterior segment imaging.
  • To demonstrate its superior diagnostic capabilities over conventional techniques.

Main Methods:

  • Utilizing Scheimpflug imaging for cross-sectional anterior segment analysis.
  • Accurate measurement of anterior and posterior corneal surfaces and lens surfaces.
  • Creation of three-dimensional reconstructions of the anterior segment.

Main Results:

  • Scheimpflug imaging accurately measures anterior and posterior corneal surfaces and lens.
  • Identifies earlier indicators of ectatic change through posterior cornea and corneal thickness mapping.
  • Provides significantly greater corneal coverage compared to Placido-based devices.

Conclusions:

  • Scheimpflug imaging offers significant advantages for anterior segment analysis.
  • It enables earlier diagnosis of corneal ectasia and peripheral diseases like pellucid marginal degeneration (PMD).
  • Enhanced corneal coverage is critical for diagnosing peripheral corneal conditions.