Related Experiment Video
Updated: May 9, 2026

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Brachial arterial temperature as an indicator of core temperature: proof of concept and potential applications
Matthew D M Pawley1, Paul Martinsen, Simon J Mitchell
1Department of Anaesthesiology, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand. m.pawley@auckland.ac.nz
Abstract:
There is potential for heat loss and hypothermia during anesthesia and also for hyperthermia if heat conservation and active warming measures are not accurately titrated. Accurate temperature monitoring is particularly important in procedures in which the patient is actively cooled and then rewarmed such as during cardiopulmonary bypass surgery (CPB). We simultaneously measured core, nasopharyngeal, and brachial artery temperatures to investigate the last named as a potential peripheral temperature monitoring site. Ten patients undergoing hypothermic CPB were instrumented for simultaneous monitoring of temperatures in the pulmonary artery (PA), aortic arterial inflow (AI), nasopharynx (NP), and brachial artery (BA). Core temperature was defined as PA temperature before and after CPB and the AI temperature during CPB. Mean deviations of BA and NP temperatures from core temperature were calculated for three steady-state periods (before, during, and after CPB). Mean deviation of BA and NP temperatures from AI temperature was also calculated during active rewarming. A total of 1862 measurements were obtained and logged from eight patients. Mean BA and NP deviations from core temperature across the steady-state periods (before, during, and after CBP) were, respectively: .23 +/- .25, -.26 +/- .3, and -.09 +/- .05 degrees C (BA), and .11 +/- .19, -.1 +/- .47, and -.04 +/- .3 degrees C (NP). During steady-state periods, there was no evidence of a difference between the mean BA and NP deviation. During active rewarming, the mean difference between the BA and AI temperatures was .14 +/- .36 degrees C. During this period, NP temperature lagged behind AI and BA temperatures by up to 41 minutes and was up to 5.3 degres C lower than BA (mean difference between BA and NP temperatures was 1.22 +/- .58 degrees C). The BA temperature is an adequate surrogate for core temperature. It also accurately tracks the changing AI temperature during rewarming and is therefore potentially useful in detecting a hyperthermic perfusate, which might cause cerebral hyperthermia.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...