Related Experiment Video
Updated: May 9, 2026

Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes
Published on: May 17, 2018
Vacuum assist: angel or demon CON
1Green Lane Cardiothoracic Unit, Auckland City Hospital, Auckland, New Zealand. timw@adhb.govt.nz
Abstract:
Vacuum-assisted venous drainage (VAVD) to enhance venous return during cardiopulmonary bypass (CPB) was described as early as 1958 but was not widely used until the late 1990s. VAVD was initially used to facilitate the use of smaller cannulas with ministernotomy but was increasingly used to allow reduction in CPB circuit size while maintaining CPB flow rates. This innovation was made without planned consideration to CPB circuit design, most critically that of the venous reservoir. Clinical reports of prime reduction facilitated by VAVD in both adult and pediatric CPB were associated with reduced nadir hematocrit and rates of transfusion that encouraged the proliferation of VAVD in CPB. Concomitantly, investigators have reported both in vitro and in vivo significantly increased arterial emboli associated with the use of VAVD, mostly related to accelerated venous air entrainment. In vitro studies continue to confirm this association and likely underestimate the resulting embolic load as a result of flawed study design. While the evidence for VAVD is equivocal, our understanding of the clinical impact of gaseous microemboli in CPB is similarly limited, most likely confined to blood-brain barrier disruption. It is only after two decades that CPB component design is receiving serious attention in terms of air handling. The ethics of innovation in the field of CPB warrant careful consideration. The application of VAVD is not without consequence.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Van de Graaff Generator
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Excess Pressure Inside a Drop and a Bubble
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...