A novel approach toward noninvasive monitoring of transcutaneous CO(2)
Madhubanti Chatterjee1, Xudong Ge1, Yordan Kostov1
1Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250, United States.
Abstract:
The continuous monitoring of transcutaneous gases is an integral part of neonatal intensive care. Present monitors measure the equilibrating values of these gases by raising the skin temperature to 42°C or above. Because neonatal skin is very sensitive and delicate, this often leads to serious skin injuries. In this work, we present a new approach to the noninvasive measurement of transcutaneous partial pressure of carbon dioxide (tcpCO2) based on the initial pseudo steady state diffusion rates instead of the mass-transfer equilibrium. Because we are following initial diffusion rates, each measurement takes no more than a few minutes. Additionally, raising the surface temperature is not required, thus, skin irritation and burns are highly unlikely. A dual-chamber diffusion vessel with either porcine skin or dialysis membrane placed between the two chambers was used to mimic neonatal skin. LI-820 CO2 Analyzer was used to measure the CO2 diffusing through the membrane or skin. Initial experiments on adult human skin under varying physical activities, food intake and breathing patterns showed a strong influence of the various conditions on the amount of CO2 diffusing through skin. These initial findings suggest that this method can be used not only on neonates but to a wider population of patients.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.