Sampling and Analysis of Animal Scent Signals
Published on: February 13, 2021
Dispersive micro solid-phase extraction for the rapid analysis of synthetic polycyclic musks using thermal desorption
Wu-Hsun Chung1, Shin-Hwa Tzing, Wang-Hsien Ding
1Department of Chemistry, National Central University, Chung-Li 320, Taiwan; Department of Chemical Engineering, Army Academy ROC, Chung-Li 320, Taiwan.
Abstract:
A simple and solvent-free method for the rapid analysis of five synthetic polycyclic musks in water samples is described. The method involves the use of dispersive micro solid-phase extraction (D-μ-SPE) coupled with direct thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) operating in the selected-ion-storage (SIS) mode. The parameters affecting the extraction efficiency of the target analytes from water sample and the thermal desorption conditions in the GC injection-port were optimized using a central composite design method. The optimal extraction conditions involved immersing 3.2mg of a typical octadecyl (C18) bonded silica adsorbent (i.e., ENVI-18) in a 10mL water sample. After extraction by vigorously shaking for 1.0min, the adsorbents were collected and dried on a filter. The adsorbents were transferred to a micro-vial, which was directly inserted into GC temperature-programmed injector, and the extracted target analytes were then thermally desorbed in the GC injection-port at 337°C for 3.8min. The limits of quantitation (LOQs) were determined to be 1.2-3.0ng/L. Precision, as indicated by relative standard deviations (RSDs), was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 and 90%. A preliminary analysis of the river water samples revealed that galaxolide (HHCB) and tonalide (AHTN) were the two most common synthetic polycyclic musks present. Using a standard addition method, their concentrations were determined to in the range from 11 to 140ng/L.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors