Related Experiment Video
Updated: May 8, 2026

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation
Published on: July 15, 2015
A novel strategy for preserving renal grafts in an ex vivo setting: potential for enhancing the marginal donor pool
Hailin Zhao1, Jiaolin Ning, Sinead Savage
11D.M., Anaesthetics, Pain Medicine and Intensive Care, Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, Chelsea and Westminster Hospital, 369 Fulham Rd., London SW10 9NH, UK. d.ma@imperial.ac.uk.
Abstract:
Renal transplantation remains the best treatment option for patients with end-stage renal failure. However, the shortage of renal grafts remains a big challenge. Renal graft ischemic injuries that occur before and after graft retrieval have a devastating effect on graft survival, especially on grafts from marginal donors. This study was conducted to assess the protective effect against ischemic injury of a preservative solution supplemented with xenon (Xe), when used on ex vivo kidney grafts in a rat renal transplant model, and to explore the underlying mechanisms in vitro. Lewis rat renal grafts were stored in Soltran preservative solution at 4°C, saturated with nitrogen (N2) or Xe gas (70% Xe or N2, with 5% CO2 balanced with O2) for 24 or 48 h. Grafts stored in Xe-saturated preservative solution demonstrated significantly less severe histopathologic changes, together with enhanced B-cell lymphoma (Bcl)-2 and heat shock protein (HSP)-70 expression. After engraftment in the Lewis rat recipient, renal function was significantly improved in the Xe-treated grafts, and macrophage infiltration and fibrosis were reduced. Xe exposure enhanced Bcl-2 and HSP-70 expression in human renal tubular epithelial (HK-2) cells and prevented mitochondrial and nuclear damage. The release of the apoptogenic factors cytochrome c, apoptosis-inducing factor (AIF), and proinflammatory high-mobility group protein B1 (HMGB-1) was effectively suppressed. This study thus demonstrated for the first time that Xe confers renoprotection on renal grafts ex vivo and is likely to stabilize cellular structure during ischemic insult. The current study has significant clinical implications, in which the use of Xe ex vivo could enhance the marginal donor pool of renal grafts by preventing graft loss due to ischemia.
Insights
Xenon (Xe) gas protects kidney grafts from ischemic injury during preservation. This study shows Xe improves graft survival and function, potentially expanding the donor pool for renal transplantation.
Area of Science:
- Nephrology
- Transplantation immunology
- Biochemistry
Background:
- Renal transplantation is the optimal treatment for end-stage renal failure, but graft shortage and ischemic injury pose significant challenges.
- Ischemic injuries severely impact graft survival, particularly for marginal donors.
- Developing strategies to mitigate ischemia-reperfusion injury is crucial for improving transplant outcomes.
Purpose of the Study:
- To evaluate the renoprotective effects of xenon (Xe) in a preservative solution for ex vivo kidney grafts.
- To investigate the underlying mechanisms of Xe-induced protection in vitro and in a rat renal transplant model.
Main Methods:
- Lewis rat kidneys were stored ex vivo in Soltran solution saturated with nitrogen (N2) or xenon (Xe) for 24 or 48 hours.
- Histopathological analysis, assessment of Bcl-2 and HSP-70 expression, and evaluation of renal function post-transplantation were performed.
- In vitro studies used human renal tubular epithelial (HK-2) cells to examine cellular damage and apoptosis markers.
Main Results:
- Xenon-preserved grafts exhibited reduced histopathological damage, increased Bcl-2 and HSP-70 expression, and improved post-transplant renal function.
- Xe treatment decreased macrophage infiltration and fibrosis in engrafted kidneys.
- In vitro, Xe enhanced protective protein expression and prevented mitochondrial and nuclear damage in HK-2 cells, suppressing the release of apoptotic factors.
Conclusions:
- Xenon confers significant renoprotection to ex vivo kidney grafts against ischemic injury.
- Xe stabilizes cellular structures during ischemia by modulating key protective pathways.
- This finding has clinical implications for enhancing the marginal donor pool by preventing graft loss due to ischemia.
Related Concept Videos
Kidney Transplant I: Introduction
Kidney Transplant II: Surgical Procedure