Related Experiment Video
Updated: May 8, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Thermography is not a feasible method for breast cancer screening
Boris Brkljacić1, Damir Miletić, Francesco Sardanelli
1University of Zagreb, School of Medicine, Dubrava University Hospital, Department of Diagnostic and Interventional Radiology, Zagreb, Croatia. boris.brkljacic@zg.htnet.hr
Abstract:
Breast cancer is a common malignancy causing high mortality in women especially in developed countries. Due to the contribution of mammographic screening and improvements in therapy, the mortality rate from breast cancer has decreased considerably. An imaging-based early detection of breast cancer improves the treatment outcome. Mammography is generally established not only as diagnostic but also as screening tool, while breast ultrasound plays a major role in the diagnostic setting in distinguishing solid lesions from cysts and in guiding tissue sampling. Several indications are established for contrast-enhanced magnetic resonance imaging. Thermography was not validated as a screening tool and the only study performed long ago for evaluating this technology in the screening setting demonstrated very poor results. The conclusion that thermography might be feasible for screening cannot be derived from studies with small sample size, unclear selection of patients, and in which mammography and thermography were not blindly compared as screening modalities. Thermography can not be used to aspirate, biopsy or localize lesions preoperatively since no method so far was described to accurately transpose the thermographic location of the lesion to the mammogram or ultrasound and to surgical specimen. Thermography cannot be proclaimed as a screening method, without any evidence whatsoever.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...