To evaluate tolerance of a new dynamic hand-wrist orthosis and effectiveness on the prevention of progressive wrist contracture and spasticity after stroke.
Method:
Chronic stroke patients (N = 6) with upper limb spasticity, who had not been able to endure a static orthosis, were provided with a custom-made dynamic orthosis. Tolerance of the orthosis was evaluated by the daily wearing time, and self-reported pain and spasticity. Effectiveness was measured by contracture of wrist and finger flexor muscles, upper limb spasticity and use of spasticity treatment. Outcome measures were collected at time of fitting of the dynamic orthosis (baseline) and after three and six months.
Results:
Five patients could endure the dynamic orthosis without discomfort for 6 hours daily during the 6-month period. Self-reported spasticity and pain decreased significantly (p < 0.05) compared to wearing the static orthosis. In comparison to baseline, the maximum passive wrist extension increased significantly from -29° to -12° (p < 0.05). Although, no significant change in spasticity was measured, the use of Botulinum Toxin injections decreased for two patients.
Conclusions:
The majority of the included chronic stroke patients tolerated the new dynamic orthosis for at least 6 hours daily and the use significantly reduced wrist contractures in a 6-month period.
More Related Videos
07:42Dual-Task Stroop Paradigm for Detecting Cognitive Deficits in High-Functioning Stroke Patients
Published on: December 16, 2022
10:15Utilizing Repetitive Transcranial Magnetic Stimulation to Improve Language Function in Stroke Patients with Chronic Non-fluent Aphasia
Published on: July 2, 2013
Related Concept Videos
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Pharmacodynamics in Geriatric Patients: Effects of Age
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Hand hygiene
Hand washing...
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Dynamic Equilibrium