Related Experiment Video
Updated: May 8, 2026

Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
Published on: April 18, 2019
[Video head impulse test or caloric irrigation?. Contemporary diagnostic tests for vestibular schwannoma]
A Blödow1, R Helbig, N Wichmann
1Klinik für Hals-, Nasen-, Ohrenheilkunde, Plastische Chirurgie und Kommunikationsstörungen, HELIOS-Klinikum Berlin-Buch Schwanebecker Chaussee 50, 13125 Berlin. alexander.bloedow@helios-kliniken.de
Abstract:
The video head impulse test (vHIT) is a new method for investigating vestibular function that is currently poorly studied in terms of its value for clinical diagnosis in otolaryngology. Both the caloric irrigation and vHIT serve to evaluate the horizontal vestibulo-ocular reflex. In the present study, caloric irrigation and vHIT were compared in 46 patients with vestibular schwannoma. Caloric irrigation exhibits a higher sensitivity than vHIT (72% versus 41%) and both tests show only a moderate correlation. Tumor size and hearing level was significantly correlated with caloric abnormalities but not with vHIT findings. Since caloric irrigation and vHIT measure the hVOR in low and high frequency ranges, respectively, these tests have to be considered complementary and are valuable in both diagnostics and therapeutic decisions.