A quantitative definition of scaphoid union: determining the inter-rater reliability of two techniques
Ruby Grewal1, Uri Frakash, Said Osman
1Department of Surgery, Division of Orthopedic Surgery, Hand and Upper Limb Center, St, Joseph's Health Care, University of Western Ontario, London, Ontario, Canada. rgrewa@uwo.ca
Background:
Despite extensive literature supporting the use of computerized tomography (CT) scans in evaluating scaphoid fractures, there has not been a consensus on the methodology for defining and quantifying union. The purpose of this study was to test the inter-observer reliability of two methods of quantifying scaphoid union.
Methods:
The CT scans of 50 non-operatively treated scaphoid fractures were reviewed by four blinded observers. Each was asked to classify union into one of three categories, united, partially united, or tenuously united, based on their general impression. Each reviewer then carefully analyzed each CT slice and quantified union based on two methods, the mean percentage union and the weighted mean percentage union. The estimated percentage of scaphoid union for each scan was recorded, and inter-observer reliability for both methods was assessed using a Bland-Altman plot to calculate the 95% limits of agreement. Kappa statistic was used to measure the degree of agreement for the categorical assessment of union.
Results:
There was very little difference in the percentage of union calculated between the two methods (mean difference between the two methods was 1.2 ± 4.1%), with each reviewer demonstrating excellent agreement between the two methods based on the Bland-Altman plot. The kappa score indicated very good agreement (Κ = 0.80) between the consultant hand surgeon and the musculoskeletal radiologist, and good agreement (Κ = 0.62) between the consultant hand surgeon and the hand fellow for the categorical assessment of union.
Conclusions:
This study describes two methods of quantifying and defining scaphoid union, both with a high inter-rater reliability. This indicates that either method can be reliably used, making it an important tool for both for clinical use and research purposes in future studies of scaphoid fractures, particularly those which are using union or time to union as their endpoint.
Level Of Evidence:
Diagnostic, level III.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
09:18Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Related Concept Videos
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Spearman's Rank Correlation Test
Spearman's test calculates correlation by...
Calibration Curves: Correlation Coefficient
Reliability and Validity
Kendall's Coefficient of Concordance
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...