Antigen recovery and preservation using the microwave irradiation of biological samples for transmission electron

Josiane Aïoun1, Sophie Chat, Christian Bordat

  • 1Institut National de la Recherche Agronomique (INRA), Unité de Recherche UR902 Nutrition et Régulation Lipidique des Fonctions Cérébrales, Jouy-en-Josas, France.

Micron (Oxford, England : 1993)
|August 22, 2013
PubMed

Insights

Microwave irradiation (MWI) improves tissue sample preparation for immunolocalization, enhancing antigen preservation and ultrastructure. This method offers comparable or superior results to conventional techniques in minimal time.

Area of Science:

  • Histology
  • Immunocytochemistry
  • Biotechnology

Background:

  • Microwave irradiation (MWI) is known to improve tissue structural integrity.
  • Limited research exists on MWI's impact on antigen preservation during sample preparation for immunolocalization.

Purpose of the Study:

  • To evaluate MWI for antigen preservation and retrieval in tissue sample preparation.
  • To compare MWI with conventional methods for morphology and antigenicity in brain and mammary gland tissues.

Main Methods:

  • Tested MWI versus conventional procedures on brain and mammary gland tissues.
  • Used immunocytochemistry to locate PPARβ/δ in hamster brain and PPARγ/caveolin-1 in mouse mammary gland.
  • Quantified immunolabeling density for caveolin-1.

Main Results:

  • MWI enabled antigen preservation and retrieval, yielding similar or better results than conventional protocols.
  • MW treatment allowed localization of PPARβ/δ in glutaraldehyde-fixed specimens, which was not possible with conventional methods.
  • Quantification showed up to a three-fold increase in caveolin-1 density in MWI-processed tissues.

Conclusions:

  • MWI significantly enhances antigen preservation and retrieval for immunolocalization.
  • Microwave techniques improve both ultrastructure and immunodetection in tissue samples.
  • MWI offers a rapid and effective alternative to conventional tissue preparation methods.

Related Concept Videos

Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...