Related Experiment Video
Updated: May 8, 2026

Aerobic Biodegradation Testing of Materials Using a Natural Marine Seawater Inoculum and Closed Loop Respirometer
Published on: October 24, 2025
Automated spectrophotometric analyzer for rapid single-point titration of seawater total alkalinity
Quanlong Li1, Fengzhen Wang, Zhaohui Aleck Wang
1State Key Laboratory of Marine Environmental Science, ‡College of the Environment and Ecology, and ∥College of Ocean and Earth Sciences, Xiamen University , Xiamen 361005, People's Republic of China.
Abstract:
An automated analyzer was developed to achieve fast, precise, and accurate measurements of seawater total alkalinity (AT) based on single-point titration and spectrophotometric pH detection. The single-point titration was carried out in a circulating loop, which allowed the titrant (hydrochloric acid and bromocresol green solution) and a seawater sample to mix at a constant volume ratio. The dissolved CO2 in the sample-titrant mixture was efficiently removed by an inline CO2 remover, which consists of a gas-permeable tubing (Teflon AF2400) submerged in a sodium hydroxide (NaOH) solution. The pH of the mixture was then measured with a custom-made spectrophotometric detection system. The analyzer was calibrated against multiple certified reference materials (CRMs) with different AT values. The analyzer features a sample throughput time of 6.5 min with high precision (±0.33-0.36 μmol kg(-1); n = 48) and accuracy (-0.33 ± 0.99 μmol kg(-1); n = 10). Intercomparison to a traditional open-cell AT titrator showed overall good agreement of 0.88 ± 2.03 μmol kg(-1) (n = 22). The analyzer achieved excellent stability without recalibration over 11 days, during which time 320 measurements were made with a total running time of over 40 h. Because of its small size, low power consumption requirements, and its ability to be automated, the new analyzer can be adapted for underway and in situ measurements.
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Titration of Polyprotic Base with a Strong Acid
Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
