Related Experiment Video
Updated: May 8, 2026

A Human Fallopian Tube Model for Investigation of C. trachomatis Infections
Published on: August 11, 2012
Use of the UriSwab collection device for testing of Chlamydia trachomatis and Neisseria gonorrhoeae: implications for
1Pathology Queensland, Central Laboratory, Molecular Diagnostic Unit, Metro North Health Service District, Brisbane, Australia.
Abstract:
In order to demonstrate the reliability of UriSwab, a trial was conducted using urine samples that had previously returned a detected result for Chlamydia trachomatis and/or Neisseria gonorrhoeae. Urine specimens (115 samples) were received from sexual health clinics and tested using the Roche Cobas 4800 CT/NG method. Concurrently, the urine samples were pipetted directly on to the sponge applicator of the UriSwab, simulating micturition, and the urine harvested from the UriSwab was tested using the Roche Cobas 4800 method. Of the 87 standard urine specimens that were C. trachomatis detected, 85 (98%) were also detected in the corresponding UriSwab specimen (sensitivity 97.7%, specificity 95.7%). Of the 34 standard specimens that were N. gonorrhoeae detected, 33 (97%) were also detected in the corresponding UriSwab specimen (sensitivity 97.1%, specificity 100%). The performance of the UriSwab in this trial was comparable with the testing of neat first-catch urine specimens for both C. trachomatis and N. gonorrhoeae.
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
Sexually Transmitted Infections
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care