Background:
With the increasing use, complexity, anatomical approaches, and tools related to epicardial procedures, complications previously not seen during endovascular ablation are now well recognized with epicardial ablation. Whether newer approaches and the regional anatomy of the pericardial space contribute to unexpected complications after epicardial access (EpiAcc) is presently unknown.
Objective:
To characterize underreported, or novel, complications associated with percutaneous EpiAcc as part of an electrophysiology procedure.
Methods:
We retrospectively reviewed percutaneous EpiAcc as part of an ablation procedure from January 1, 2004, to December 31, 2011.
Results:
Of 116 attempts in 107 patients, 8 atypical ablation complications (no procedural deaths) were noted; complications included delayed pericarditis (2 weeks), chronic refractory pericarditis, requirement for snaring of broken intrapericardial wire, pleural perforation, phrenic nerve injury despite protective strategies, hemoperitoneum, and abdominal-pericardial fistula.
Conclusion:
Vigilance both during and after EpiAcc is needed to recognize these complications, some of which may be life-threatening.
More Related Videos
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Mechanism of Cardiac Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias III: Characteristics of Dysrhythmias