Effects of propofol on patient-ventilator synchrony and interaction during pressure support ventilation and neurally
Rosanna Vaschetto1, Gianmaria Cammarota, Davide Colombo
11Anesthesia and Intensive Care, "Maggiore Della Carità" Hospital, Novara, Italy. 2Anesthesia and Intensive Care, Department of Translational Medicine, Eastern Piedmont University "A. Avogadro," Novara, Italy. 3Anesthesia and Intensive Care, Sant'Andrea Hospital, ASL VC, Vercelli, Italy. 4CRRF Mons. L. Novarese, Moncrivello (VC), Vercelli, Italy.
Objectives:
Evaluating the physiologic effects of varying depths of propofol sedation on patient-ventilator interaction and synchrony during pressure support ventilation and neurally adjusted ventilatory assist.
Design:
Prospective crossover randomized controlled trial.
Setting:
University hospital ICU.
Patients:
Fourteen intubated patients mechanically ventilated for acute respiratory failure.
Interventions:
Six 25-minute trials randomly performed applying both pressure support ventilation and neurally adjusted ventilatory assist during wakefulness and with two doses of propofol, administered by Target Control Infusion, determining light (1.26 ± 0.35 μg/mL) and deep (2.52 ± 0.71 μg/mL) sedation, as defined by the bispectral index and Ramsay Sedation Scale.
Measurements And Main Results:
We measured electrical activity of the diaphragm to assess neural drive and calculated its integral over time during 1 minute (∫electrical activity of the diaphragm/min) to estimate diaphragm energy expenditure (effort), arterial blood gases, airway pressure, tidal volume and its coefficient of variation, respiratory rate, neural timing components, and calculated the ineffective triggering index. Increasing the depth of sedation did not cause significant modifications of respiratory timing, while determined a progressive significant decrease in neural drive (with both modes) and effort (in pressure support ventilation only). In pressure support ventilation, the difference in ineffective triggering index between wakefulness and light sedation was negligible (from 5.9% to 7.6%, p = 0.97); with deep sedation, however, ineffective triggering index increased up to 21.8% (p < 0.0001, compared to both wakefulness and light sedation). With neurally adjusted ventilatory assist, ineffective triggering index fell to 0%, regardless of the depth of sedation. With both modes, deep sedation caused a significant increase in PaCO2, which resulted, however, from different breathing patterns and patient-ventilator interactions.
Conclusions:
In pressure support ventilation, deep propofol sedation increased asynchronies, while light sedation did not. Propofol reduced the respiratory drive, while breathing timing was not significantly affected. Gas exchange and breathing pattern were also influenced by propofol infusion to an extent that varied with the depth of sedation and the mode of ventilation.
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: