Related Experiment Video
Updated: May 8, 2026

Laryngeal Mask Airway (LMA) Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway (SGA)
Published on: July 14, 2023
Comparison of classic laryngeal mask airway with Ambu laryngeal mask for tracheal tube exchange: A prospective
Shruti Jain1, Rashid M Khan, Syed M Ahmed
1Department of Anesthesiology, School of Medical Sciences and Research, Sharda University, Greater Noida, India.
Background And Aim:
Exchanging endotracheal tube (ETT) with classic laryngeal mask airway™ (CLMA™) prior to emergence from anaesthesia is a safe technique to prevent the coughing and haemodynamic changes during extubation. We had compared CLMA™ and AMBU laryngeal mask™ (ALM™) during ETT/laryngeal mask (LM) for haemodynamic changes and other parameters.
Methods:
A total of 100 American Society of Anesthesiologist Grade I and II adult female patients undergoing elective laparoscopic cholecystectomy under general anaesthesia were selected and randomly divided into two groups of 50 patients each. In Group I, CLMA™ and in Group II, ALM™ was placed prior to tracheal extubation. Haemodynamic parameters were recorded during ETT/LM exchange. Glottic view was seen through the LM using flexible fibrescope. Coughing/bucking during removal of LM, ease of placement and post-operative sore throat for both groups were graded and recorded.
Statistical Analysis:
Data within the groups was analysed using paired t-test while between the groups was analysed using unpaired t-test. Chi-square test was used to analyse grades of glottic view, coughing, and post-operative sore throat.
Results:
In Group I, there was a significant rise in systolic blood pressure and heart rate in contrast to insignificant rise in Group II. Glottis view was significantly better in Group II. Incidence of coughing, ease of placement and post-operative sore throat was identical between both groups.
Conclusion:
ALM™ is superior to CLMA™ for exchange of ETT before extubation due to greater haemodynamic stability during exchange phase and is better positioned.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

