Related Experiment Video
Updated: May 8, 2026

Biomass Conversion to Produce Hydrocarbon Liquid Fuel Via Hot-vapor Filtered Fast Pyrolysis and Catalytic Hydrotreating
Published on: December 25, 2016
Dry-heat sterilization of parenteral oil vehicles
T C Kupiec1, P Matthews, R Ahmad
1Analytical Research Laboratories, Edmond, OK.
Abstract:
The purpose of this study was to evalutate the effect of temperature and time on the dry-heat sterilization conditions of cottonseed, peanut and sesame-seed oils used as vehicles for parenteral drugs. The three oils were inidividually spiked wiht Bacillus subtilis spores and exposed to dry heat at four temperatures (150, 160, 170, and 180 deg C) for three different time intervals (one, 1.5 and two hours). Following inoculation and dry-heat sterilization, samples were placed in a laminar airflow hood and processed according to 71, "Sterility Tests" of the USP XXIV/NF 19 using thioglycolate broth and fluid D. The specimens were then placed into an incubator at 30 deg C and observed for three, five and seven days for bacterial growth. All tests were performed in triplicate. Positive and negative controls were conducted with each group. All three oils were found to be free of viable Bacillus subtilis following dry-heat sterilization at 150, 160, 170 and 180 deg C for one, 1.5 and two hours after incubation for seven days. The positive controls had no observed bacterial growth. Dry-heat sterilization of the three oils at 150 deg C for one hour appeared to be sufficient for time and temperature conditions. However, the authors recommend dry-heat sterilization procedures be validated for each product.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...