Related Experiment Video
Updated: May 8, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Effect of cementation technique of individually formed fiber-reinforced composite post on bond strength and
Dominika Makarewicz1, Anna-Maria B Le Bell-Rönnlöf, Lippo V J Lassila
1Department of Biomaterials Science, Institute of Dentistry and BioCity Turku Biomaterials Research Program, University of Turku, FI-20520, Turku, Finland.
Objectives:
The aim of this study was to evaluate the effect of two different cementation techniques of individually formed E-glass fiber-reinforced composite (FRC) post on bond strength and microleakage.
Methods:
The crowns of extracted third molars were removed and post preparation was carried out with parapost drills (diameter 1.5 mm). After application of bonding agents individually formed FRC posts (everStick POST, diameter 1.5 mm) were cemented into the post spaces with either ParaCem®Universal or self-adhesive RelyX™Unicem, using two different cementation techniques: 1) an "indirect (traditional) technique" where the post was prepolymerized prior application of luting cement and insertion into the post space or 2) a "direct technique" where the uncured post was inserted to the post space with luting cement and light-polymerized in situ at the same time. After water storage of 48 hours, the roots (n = 10/group) were cut into discs of thickness of 2 mm. A push-out force was applied until specimen fracture or loosening of the post. A microleakage test was carried out on roots which were not subjected to the loading test (n= 32) to evaluate the sealing capacity of the post-canal interface. The microleakage was measured using dye penetration depth under a stereomicroscope.
Results:
Higher bond strength values (p<0.05) and less microleakage (p<0.05) were obtained with the "direct technique" compared to the "indirect technique". None of the FRC posts revealed any dye penetration between the post and the cement.
Conclusions:
The "direct technique" seems to be beneficial when cementing individually formed FRC posts.
Related Concept Videos
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Bonding and Strength of Aggregate
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Microcracking in Concrete
Pore Size Distribution
Adequate...
