Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

The Vestibular System01:29

The Vestibular System

The vestibular system is a set of inner ear structures that provide a sense of balance and spatial orientation. This system is comprised of structures within the labyrinth of the inner ear, including the cochlea and two otolith organs—the utricle and saccule. The labyrinth also contains three semicircular canals—superior, posterior, and horizontal—that are oriented on different planes.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Mapping Aural Rehabilitation Needs in a Kannada-Speaking Population: A Focus Group Study with Adults with Hearing Loss, Their Significant Others and Audiologists.

Audiology research·2026
Same author

Exploring research trends in decreased sound tolerance: A preliminary scientometric review.

Acta psychologica·2026
Same author

Association between Tinnitus and Auditory Middle Latency Response: An Exploratory Study.

Journal of otology·2026
Same author

The Effect of Age on Sentence Recognition in Noise with Different Noises Across the Adult Lifespan.

Audiology research·2026
Same author

The Effect of Modulation Enhancement Scheme on Speech Recognition in Spatial Noise Among Young Adults with Normal Hearing.

Audiology research·2026
Same author

Vestibular Function in Long-Term Hearing Aid Users: A Preliminary Investigation.

Audiology research·2026

Related Experiment Video

Updated: May 8, 2026

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
10:12

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform

Published on: May 23, 2013

Ocular vestibular evoked myogenic potential using different test stimuli.

Dessai Teja Deepak1, Jayashree S Bhat, Kaushlendra Kumar

  • 1Department of Audiology & Speech Language Pathology, Kasturba Medical College, Manipal University, Mangalore 575 001, India.

ISRN Otolaryngology
|August 30, 2013
PubMed
Summary

Comparing auditory stimuli for ocular evoked myogenic potentials (oVEMP), this study found 500 Hz stimuli yield better latency and amplitude than click stimuli. This suggests 500 Hz may improve vestibular dysfunction diagnosis using oVEMP.

More Related Videos

Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane
07:24

Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane

Published on: August 22, 2025

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

Related Experiment Videos

Last Updated: May 8, 2026

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
10:12

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform

Published on: May 23, 2013

Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane
07:24

Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane

Published on: August 22, 2025

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

Area of Science:

  • Neuroscience
  • Audiology
  • Vestibular System

Background:

  • Ocular Evoked Myogenic Potentials (oVEMP) are valuable for assessing vestibular function.
  • Different acoustic stimuli may influence oVEMP response characteristics.

Purpose of the Study:

  • To compare the efficacy of click, 500 Hz mixed modulated, and 500 Hz short duration tone burst stimuli in evoking oVEMP.
  • To determine which stimulus provides optimal parameters for clinical oVEMP testing.

Main Methods:

  • Sixty healthy subjects underwent contralateral oVEMP testing with a 30-degree upward gaze.
  • Single-channel electrode montage was used to record oVEMP responses.
  • Three stimuli types were applied: click, 500 Hz mixed modulated, and 500 Hz short duration tone burst.

Main Results:

  • All three stimuli achieved 100% response rates.
  • Click stimuli showed significantly earlier latency and lower peak-peak amplitude compared to 500 Hz stimuli.
  • No significant difference in n1-p1 latency or peak-peak amplitude was found between the two 500 Hz stimuli.

Conclusions:

  • 500 Hz stimuli (both modulated and tone burst) demonstrate superior latency and peak-peak amplitude for oVEMP compared to click stimuli.
  • The use of 500 Hz stimuli may enhance the sensitivity and morphological quality of oVEMP responses.
  • 500 Hz stimuli show promise for improving the clinical diagnosis of vestibular dysfunction via oVEMP testing.